PD cable & power testing

We test power paths that include PD cables, varying voltage and load. Starting with Reference Cable A, we also publish measurements of Framework, DAISO and other cables. Recording conditions and test history helps make comparisons meaningful.

We compare measurements with available PD communication records, separating observations, reproduction conditions and untested areas. These records support product understanding and technical discussions with manufacturers.

CABLE POWER PATH RECORDS

Cable measurements, with reports to explore.

Reference Cable A is our starting point for comparison.
Explore examples of 2m and 1m cables, too.

FEATURED CABLE / 2026.10.17

A starting point for comparison / anonymized public edition

Comparison reference
Cable AReference A / 1.0 m

Fixed 5–48V current round trips, loaded holds at each voltage, before/after light-load checks and a return from 48V to 5V. All 29 planned cases completed in one run with the same software.

29 / 29PASS under the recorded conditions
Completed in one run
48V / 5AHighest setpoint
Measured at the load side
120 sLoaded hold at each voltage
120 samples per hold

Load-side medians at the 48V / 5A setpoint
47.263V / 5.000A / 236.315W

240W is the nominal product of set voltage and load current. Measurements include the effects of the source, cable, connectors and PD recording instrument in the path; they are not isolated cable performance figures.

Test object
Power path including one cable
AC input
100Vac / 50Hz (operator-entered settings)
Acquisition
One run / control software v5.8.13
Measured 17 October 2026
Reports
6 pages each in Japanese & English / issued 17 October 2026

The manufacturer, model and identifying information are withheld in this public edition. This is a comparison-reference candidate for the same path and settings, with qualifications. The reports retain two control-log warnings and the follow-up checks. It is not a calibration standard or verification of USB-IF certification.

Read English PDF ↗

6 pages / approx. 127 KB / anonymized public edition, 20 October 2026

Japanese PDF ↗
Simplified Chinese PDF ↗

6 pages / Simplified Chinese translation

Traditional Chinese (Taiwan) PDF ↗

6 pages / Traditional Chinese (Taiwan) translation

Download the measurement data package ZIP / approx. 3.0 MB ↓

CABLE / 2026.10.21

ChargerLABPOWER-Z AK001 / 1.5 m

This 1.5 m cable displays voltage, current and power while charging. The record covers 29 Fixed 5–48 V power tests and display comparisons at seven video moments.

Median at the receiving test-device input, with 48 V / 5 A settings
47.252V / 236.262W

Display comparison: seven video moments
The cable current display was approximately 7.9–10.4% higher than the ASD test-device display. This example distinguishes completion of power tests from display accuracy.

Test object
Power path including one cable specimen
AC input
100Vac / 50Hz (operator-entered settings)
Coverage
All 29 cases PASS in one run
Reports
6 pages in each of 4 languages / measured October 21, 2026

Display differences are relative comparisons at seven selected moments, not calibrated absolute errors. Loaded tests used a ±1.5 V voltage stop band. The reports retain unresolved identity acquisitions, control-response warnings and scope limits.

CABLE / 2026.10.21

ZiwuniuCM1 / 1.2 m

This 1.2 m cable has a display unit. The record covers 29 Fixed 5–48 V power tests, a whole-path comparison with Reference A, and display comparisons at seven video moments.

Median at the receiving test-device input, with 48 V / 5 A settings
47.183V / 235.915W

Display comparison: seven video moments
The cable current display was approximately 6–10% lower than the ASD test-device display. Video observations at a 5 A setting show 4.6–4.7 A on the cable against 5.000 A on the ASD.

Test object
Power path including one cable specimen
AC input
100Vac / 50Hz (operator-entered settings)
Coverage
All 29 cases PASS in one run
Reports
6 pages in each of 4 languages / measured October 21, 2026

Display differences are relative comparisons at seven selected moments, not calibrated absolute errors. Loaded tests used a ±1.5 V voltage stop band. The reports retain unresolved identity acquisitions, control-response warnings and scope limits.

CABLE / 2026.10.19

FrameworkUSB-C Cable - EPR / 2.0 m

A 2m EPR cable tested with Fixed 5–48V current round trips, 120-second loaded holds at each voltage and a return to 5V. Comparison with the 1m Reference Cable A record documents power-path differences that include cable-length differences.

Load-side medians at the 48V / 5A setpoint
47.177V / 5.000A / 235.885W

Test object
Power path including one cable
AC input
100Vac / 50Hz (operator-entered settings)
Coverage
29 accepted cases / completed across two runs
Reports
6 pages each in Japanese & English / issued 19 October 2026

The first run stopped when the capture instrument’s USB readout stalled, before measurements for the last case. Retesting the final 48V-to-5V return provided successful records for all 29 cases. This is distinct from uninterrupted completion in one run. Differences from Reference Cable A include 2m versus 1m length, contacts, measurement time and control paths; they do not establish isolated cable resistance or superiority.

Read English PDF ↗

6 pages / approx. 161 KB / anonymized public edition, 20 October 2026

Japanese PDF ↗
Simplified Chinese PDF ↗

6 pages / Simplified Chinese translation

Traditional Chinese (Taiwan) PDF ↗

6 pages / Traditional Chinese (Taiwan) translation

Download the measurement data package ZIP / approx. 2.8 MB ↓

CABLE / 2026.10.19

DAISOYMU-25-P10 / G273-011 / 1.0 m

A nominal 1m cable completed Fixed 5–48V current round trips, 120-second loaded holds at each voltage and a return to 5V in one run. Comparison with the also-nominal-1m Reference Cable A record explores voltage-droop differences in the power path.

Load-side medians at the 48V / 5A setpoint
47.051V / 5.000A / 235.255W

Test object
Power path including one cable
AC input
100Vac / 50Hz (operator-entered settings)
Coverage
All 29 cases PASS in one run
Reports
6 pages each in Japanese & English / issued 19 October 2026

At 5A, voltage droop was approximately 207–210mV greater than the reference record. This includes source, contact, measurement-path and separate-time effects; it is not converted to isolated cable resistance or a standards-compliance judgment. USB data transfer was not tested, so this is not a measurement of actual data speed.

Read English PDF ↗

6 pages / approx. 162 KB / anonymized public edition, 20 October 2026

Japanese PDF ↗
Simplified Chinese PDF ↗

6 pages / Simplified Chinese translation

Traditional Chinese (Taiwan) PDF ↗

6 pages / Traditional Chinese (Taiwan) translation

Download the measurement data package ZIP / approx. 2.8 MB ↓

48V × 5A = 240W is a nominal setpoint. Measurements are taken at the load side of a path including the cable, connectors and PD recording instrument; they do not represent isolated cable resistance or loss. Each PASS applies to the screening criteria stated in the report. USB data performance, thermal behavior, insulation, durability, certification, all plug orientations and 230Vac were outside these cable tests.

SOURCE VALIDATION RECORDS

Power-source behavior, with conditions recorded.

Examples of power-source (SRC) testing.
Exploring behavior under different input and load conditions.

SOURCE / 2026.10.19

FrameworkFRANDVCH00 / C1

Independent test suites at 100Vac and 230Vac recorded Fixed, SPR AVS and EPR AVS load round trips, 120-second loaded holds and returns to 5V. This source-focused example uses the 1m Reference Cable A in its power path.

Load-side power medians at the 48V / 5A setpoint
100Vac:236.285W / 230Vac:236.270W

Test object
One source + Reference Cable A 1m power path
AC input
100Vac / 230Vac, 50Hz (operator-entered settings)
Coverage
One source / 33 cases per input, 66 cases PASS in total
Reports
7 pages each in Japanese & English / issued 19 October 2026

One run per AC input, on one source specimen. PPS was absent from the observed PDOs and was not tested. Five concatenated-response events and four unanswered auxiliary CC readbacks remain documented as acquisition qualifications. This does not isolate the effect of AC input or establish USB-IF compliance.

Read English PDF ↗

7 pages / approx. 130 KB / anonymized public edition, 20 October 2026

Japanese PDF ↗
Simplified Chinese PDF ↗

7 pages / Simplified Chinese translation

Traditional Chinese (Taiwan) PDF ↗

7 pages / Traditional Chinese (Taiwan) translation

Download the measurement data package ZIP / approx. 3.1 MB ↓

CASE 01 / ANONYMOUS

Source A100Vac / 230Vac anonymized validation record

Testing power-delivery differences by input condition and specimen. High-load behavior, PPS and light-load voltage changes are documented with reproduction procedures and evidence IDs.

Test object
Two source specimens + comparison-source control tests
AC input
100Vac / 230Vac, 50Hz
Coverage
61 main measurement runs (including one control run)
Reports
8 pages each in Japanese & English / revision 2.1 / issued 15 October 2026

A distribution edition with names and identifying labels anonymized. Observed results are distinguished from issues whose causes remain unconfirmed.

CASE 02 / FUNCTIONAL SCREENING

PhihongAA240U-59FKEA-R

One source with a captive lead was evaluated. Records cover Fixed, PPS and EPR AVS load round trips, 60-second holds and light-load returns to 5V.

Test object
One integrated source / captive lead 1.0m
AC input
100Vac / 230Vac, 50Hz
Coverage
37 independent tests per input, 74 in total
Reports
8 pages each in Japanese & English / revision 1.0 / issued 15 October 2026

All 74 tests completed within the specified screening tolerances. PASS applies to those conditions; it is not a certification, production-quality guarantee or long-term durability judgment.

Test scope, setup and criteria differ between reports; please consult each document. Values are measured at the load side of the connected path and include path losses. The 60-second holds in some source examples do not establish hours-long operation or source-body thermal behavior.

TEMPERATURE MEASUREMENT

Temperature at chosen points. Finding hot spots.

We can discuss temperature measurements for sources, cables and connectors, based on the points and load conditions you wish to examine.

01 / THERMOCOUPLE

4-channel thermocouple thermometer

Thermocouples attached at specified points can measure up to four locations simultaneously.

02 / THERMAL CAMERA

Thermal camera

We can locate surface hot spots with a thermal camera and then measure those points using thermocouples.

The published examples do not include temperature measurements of source bodies, cables or plugs.
Instrument-internal temperatures in the logs are not used to evaluate product heating. Temperature tests are arranged separately, with the object, locations, load and hold time agreed in advance.

01 / SET CONDITIONS

Record the conditions

We document input, load and setup to compare behavior between specimens and conditions.

02 / CHECK ACTUAL OUTPUT

Check actual output

We look beyond test completion, distinguishing the requested conditions from actual measured voltage and current.

03 / KEEP EVIDENCE

Keep traceable evidence

Measurement logs and reproduction steps distinguish confirmed observations from unresolved causes.

Purpose of testing
These are functional evaluations and fault-reproduction tests informed by real-use scenarios. We do not provide USB-IF certification tests or standards-compliance judgments.

About cable evaluation
We publish initial tests of power paths that include cables. Test sequences are still being refined. These examples are not evaluations of every cable property or performance guarantees for our planned products.